讀書心得 呼吸器原理及應用 筆記
拔管生理參數
l
P0.1 > -6 cm H2O
l
P imax <-20至-30 cm H2O
l Minute ventilation < 10至15 L/min
l Tidal volume> 4至6 ml/kg (IBW)
l
F < 35
l
f/Vt <60至150 breaths/min/L
l
PaO2/FiO2 > 250 mmHg
p185,靈敏度設定不適當和流速設定不足,是導致病人和呼吸器不同步的兩個原因。
插管病人 resistence約 6cmH2O, compliance 男 40-50, 女 35-45ml/cmH2O
其他常用公式
AaDO2 = (713 x FiO2) – (pCO2 / 0.8) – (paO2)
P= F*R + V/C
有興趣可到力大書局購買....
2012-9 update:
P(A-a) O2 正常值約是 5mmHg,隨年紀增加, 十年增加4mmHg左右
PL (transpulmonary pressure) = PA (transalveolar pressure) - Ppl (transpleural pressure)
Ppl 可借由食道壓力來幫助測量
Pneumothorax in chest echo
Right lung
Left lung M-mode showed stratosphere sign
TB with hydropneumothorax
Curtain sign: hydropneumothorax
Ultrasonographic approach to diagnosing hydropneumothorax
Chest. 1992 Apr;101(4):931-4
needle aspiration 也可用在 spontaneous pneumothorax
A randomized controlled trial comparing minichest tube and needle aspiration inoutpatient management of primary spontaneous pneumothorax
Am J Emerg Med. 2011 Nov;29(9):1152-7
Aspiration versus tube drainage in primary spontaneous pneumothorax: a randomised study
Eur Respir J. 2006 Mar;27(3):477-82